Tel.: 8615989623158
E-mail: sales@grandetop.com
Alternating Mould Test Chamber It is one must-have test equipment for college, medical, military, electronic, chemical, and biological scientific research departments to conduct bacteria storage and biological cultivation test, and can be used to test and judge the parameters and properties of test specimens after exposed to humid-heat temperature environment.
Alternating Mould Test Chamber It is one must-have test equipment for college, medical, military, electronic, chemical, and biological scientific research departments to conduct bacteria storage and biological cultivation test, and can be used to test and judge the parameters and properties of test specimens after exposed to humid-heat temperature environment.
Introduces imported original Japan UNIQUE temperature and humidity controller, 7’’ HD true color LCD touch display to bring you dignity and comfort in touch and vision.
The controller has a USB port so that the data can be browsed or printed through ITAG printer under drive of the port (optional).
Shallow groove humidification method
Humidifier control method: Contact-less equal-period pulse-width modulation, SSR (Solid State Relay),Water level automatic compensation and water shortage alarming system
Humidity control introduces the same channel coordination control method of P.I.D + S.S.R system.
Refrigeration principle and compressor: In order to meet the requirements of test chamber on temperature decrease rate and lowest temperature, the test chamber's refrigeration system introduces the cascade refrigeration system composed of imported compressor, and boasts such advantages as reasonable matching, high reliability, easy operation and maintenance and so on.
Technical parameters:
Model No | GMT-100-RM | GMT-225-RM | GMT-500-RM | GMT-1000-RM |
Working room(L) | 100 | 225 | 500 | 1000 |
Inner chamber size(mm)W*H*D | 450*450*500 | 500*600*750 | 700*800*900 | 1000*1000*1000 |
Exterior chamber size(mm)W*H*D | 1200*1000*165 0 | 1300*1150*1900 | 1450*1400*2100 | 1850*1600*2250 |
Packaging volume(CBM) | 2 | 3 | 4.5 | 6 |
G.W.(KGs) | 300 | 320 | 360 | 390 |
Temperature range | 20℃~80℃ | |||
Humidity range | 45~98%RH | |||
Volatility / Uniformity | ≤0.5℃/≤2℃(No Loading) | |||
Humidity deviation | +2、-3%RH | |||
Temperature increase rate | 1.0~3.0℃/min | |||
Temperature decrease rate | 0.7~1.2℃/min | |||
Controller | Imported original Japan UNIQUE temperature and humidity controller | |||
Accuracy range | Setting accuracy: Temperature 0.1℃、 Humidity 1%RH,Indication accuracy: Temperature 0.1℃、 Humidity 1%RH | |||
Customized service | Welcome to Non-standard,Specail requirements,OEM/ODM orders. | |||
The technical information will be subjected to change without notice |