Tel.: 8615989623158
E-mail: sales@grandetop.com
Vacuum Limit: 20Pa;1Pa;0.1Pa;~0.1mmHg;0.05Torr;1*10-5Pa;1*10-7mbar
Indoor temperature:+10℃~50℃, 100℃, 150℃, 200℃, 250℃, 300℃, 350℃, 500℃, 600℃, 700℃, 800℃, 900℃, 1000℃, 1200℃, 1400℃, 1600℃, 1800℃, 2000℃, 2500℃, 3000℃.
Customization is available, Attractive appearance, widely use, Safe and reliable.
UHV Ultra High Vacuum Oven
Vacuum Oven is Widely used in biochemicalm,chemical and pharmaceutical,health care,agricultural research,environmental protection and other research applications for power drying and roasting,as well as disinfection and sterilization of glass containers used.Particularly suitable for drying heat-sensitive, easily decomposed,and the complex composition of easily oxidized material items for fast and efficient drying.
Especially designed for drying heat-sensitive, easy-to-decompose and easy-to-oxidize substances, it is able to inject inert gas internally, in Particular, it can even dry the substances with complex ingredients fast. It is widely used in electronic and chemical industries.
High quality materials,Good sealed,Convenient and Practical
Material of outer case The housing is processed and formed with high-quality (t=1.2mm) A3 color plates through CNC machine with surface sprayed with plastics, looking smoother and more artistic;Material of inner case Imported high-grade stainless steel (SUS304 or SUS316L).
Special structure,Durable and operate easily
The tension of closed chamber door can be adjusted, and integral-formed silicone rubber seal can ensure high vacuum degree inside the chamber.
Door handle: Introduce the door handle without counteraction for easy operation.
High performance,efficiency and speed
Introducing IR Ni-Cr alloy high-speed heating electric heater
Totally independent high-temperature system shall not affect low temperature test, high temperature test and alternating hot and humid test.
The output power of temperature & humidity control shall be calculated by micro computer to achieve electricity use benefits of high precision and high efficiency.
Feedthroughs
Custom-made feedthoughs and Options are acceptable.
Drawing and Pictures for reference only.
Optional accessories
USB,RS-485 interface can be linked to Personal Computer(PC) and achieve multi-level control & recording software management.
Technical Parameters:
Model No | GVO-072 | GVO-100 | GVO-270 | GVO-480 | GVO-600 | GVO-720 | GVO-1000 | |
Volume(L) | 72 | 270 | 480 | 600 | 720 | 1000 | ||
Inner chamber size(mm)W*H*D | 450*400*400 | 400*500*500 | 600*750*600 | 800*800*750 | 1000*800*750 | 1000*720*1000 | 1000*1000*1000 | |
Exterior chamber size(mm)W*H*D | 900*1550*550 | 900*1650*800 | 1100*1600*650 | 1200*1700*840 | 1400*1750*840 | 1750*1750*1200 | 1750*1750*1500 | |
Temperature range | RT+10℃~+150℃,200℃,300℃,350℃,500℃,600℃,700℃,800℃,900℃,1000℃,1200℃,1400℃,1600℃,1800℃,2000℃,2500℃,3000℃, Customization is available | |||||||
Vacuum Limit | Atmospheric pressure~1kPa;~133Pa,100Pa;1Pa;0.1Pa;~-0.1MPa;~0.1mmHg;0.05Torr;1*10-5Pa;1*10-7mbar | |||||||
Final Vacuum | 1,No loading,≧1*10-5Pa2,Loading,≧1*10-4Pa. | |||||||
Performance | Temperature Fluctuation | ±0.5℃ | ||||||
Temperature Uniformity | Atmospheric pressure:±2℃.1kPa Vacuum state:±10℃.(Options:±5℃,±10℃,±15℃,±30℃) | |||||||
Temperature Resolution | 0.1℃ | |||||||
Heating up Time | RT+10℃~250℃<90min(Nonlinear,No load)RT+10℃~400℃<120min(Nonlinear,No load) | |||||||
Material | Exterior Chamber Material | Stainless steel plate+ Power Coated | ||||||
Inner Chamber Material | SUS#304 Stainless Steel Heater, Molybdenum / Isostatic Graphite,Infrared heating array,Infrared heating cage | |||||||
Insulation Material | PU& Fiberglass wool | |||||||
System | Circulation System | 1.UHV Magnetic Motor & Fans(Options) 2.Multi-wing centrifugal circulating fan,strengthen axis and hot cold resistance rotary vane make of aluminum alloy,in order to forced convection.4.FLOW THROW Air Supply Method,level diffuse vertical heat exchange arc circulation.4.Program automatic control high speed air cylinder drive high low temperature air supply valve conversion. | ||||||
Heating System | SUS#304 stainless steel high-speed heater | |||||||
Controller | 7Inch or 15 Inch TH5600 PID PLC ControllerPopular PID PLC controller with touch-screen operationStores 120 different profiles with up to 1200 steps each (ramp, soak, jump, auto-start, end)Step types include: ramp, soak, jump, auto-start, and endEthernet interface for remote monitoring and operationRECOMMENDED OPTIONSDry air purge, to compensate for quickly shrinking air during cooling, as well as to reduce risk of condensation.Product temperature control, allows feedback from a second sensor on the product. Ensures faster completion of transition steps.Options:Siemens or Mitsubishi PLC | |||||||
Vaccuum System | Equipped with vacuum pumpMicro Dry PumpOiled Sealed Vacuum PumpDual Stage Rotary Vane Vacuum PumpDry PumpRoots PumpLiquid Ring Vacuum PumpDiffusion pump Molecular PumpCryo PumpIon PumpCentral Vacuum Unit.,etc | |||||||
Other Components | control status indicator lights, loading shelves(2pcs for free) | |||||||
Safety Protection Device | Over-heat protection circuit breaker,Control system overload protection,Overload indicator lamp. | |||||||
Power Supply | AC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz | |||||||
Customized Service | Welcome to Non-standard and Special requirements,OEM/ODM orders.Customization of inner chamber size, temperature&humidity range,etc. | |||||||
The technical information will be subjected to change without notice |